Add to Cart
13x Molecular Sieve Desiccant Removal Of CO2 And Moisture From Air (Air Pre-Purification) And Other Gases
Introduction
Molecular Sieve 13X is the sodium form of the type X crystal and has a much larger pore opening than the type A crystals. It will adsorb molecules with a kinetic diameter of less than 9 Angstrom (0.9 nm) and exclude those larger.
It also has the highest theoretical capacity of the common adsorbents and very good mass transfer rates. It can remove impurities too large to fit into a type A crystal and is commonly used to separate nitrogen from oxygen.
Technical Parameter
Molecular Sieve 13X Typical Physical Properties | ||||
Items | Unit | 8*12 Mesh | 4*6 Mesh | |
Bead Size | mm | 1.6-2.5 | 3.0-5.0 | |
Bulk Density | g/ml ≥ | 0.68-0.85 | 0.65-0.80 | |
Equilibrium Water Capacity @ 25℃ | wt% ≥ | 24.0-27.0 | 24.0-27.0 | |
Equilibrium Carbon Dioxide Capacity | wt% ≥ | 18 | 18 | |
Heat of Adsorption | BTU/lb of H2O | 1800 | 1800 | |
Crush Strength | Point Contact | N ≥ | 30-80 | 80-130 |
Variation Coefficient | - | 0.3 | 0.3 | |
Attrition Rate | wt% ≤ | 0.1 | 0.1 | |
Size Qualification | % ≥ | 97 | 97 | |
Package Moisture | wt% ≤ | 1.5 | 1.5 | |
The interval value of the indexes above are on the basis of the different grade of Molecular Sieve 13X |
Typical Application
a) Removal of CO2 and moisture from air (air pre-purification) and other gases.
b) Separation of enriched oxygen from air.
c) Removal of n-chained compositions from aromatics.
d) Removal of R-SH and H2S from hydrocarbon liquid streams (LPG, butane etc.)
e) Catalyst protection, removal of oxygenates from hydrocarbons (olefin streams).
f) Production of bulk oxygen in PSA units.
Regeneration:
Molecular sieve Type 13X can be regenerated by either heating in the case of thermal swing processes; or by lowering the pressure in the case of pressure swing processes.
To remove moisture from a 13X molecular sieve, a temperature of 250-300°C is required. A properly regenerated molecular sieve can give moisture dew points below -100°C, or mercaptan or CO2 levels below 2 ppm.
The outlet concentrations on a pressure swing process will depend on the gas present, and on the conditions of the process
Attention
Pls avoid damp and pre-adsorption of organic before running, or it must be reactivated.