Xi'an Lvneng Purification Technology Co.,Ltd.

Xi'an Lvneng Purification Technology Co., Ltd. We serve you wholeheartedly !

Manufacturer from China
Verified Supplier
8 Years
Home / Products / Zeolite Molecular Sieves /

Granular Molecular Sieve Dehydration Beige High Adsorption Capacity

Contact Now
Xi'an Lvneng Purification Technology Co.,Ltd.
Visit Website
Contact Now

Granular Molecular Sieve Dehydration Beige High Adsorption Capacity

Ask Latest Price
Video Channel
Brand Name :Xi'an Lvneng
Model Number :3A, 4A ,5A, 13x molecular sieve
Certification :ISO9001:2008
Place of Origin :Shaanxi,China
MOQ :10 Kilograms
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :50 Tons/ per Month
Delivery Time :3-15 work days
Packaging Details :1. Carton Drum/25KG 2. Carton Box/25KG; 3. Iron Drum/150KG
Shape :Granular,Pellet
Color :Beige
Size :2.0-3.0mm, 3.0-5.0mm,4.0-6.0mm
CAS NO :63231-69-6
Package Moisture :≤ 1.5%
Attrition Rate :≤ 0.1%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

3A 4A 5A 13X Zeolite Molecular Sieve For Air Separation Desiccant

Products Introduction

3A molecular sieve use: drying of various liquids (such as ethanol); drying of air; drying of refrigerants; drying of natural gas and methane gas; drying of unsaturated hydrocarbons and cracking gas, ethylene, acetylene, propylene, butadiene.

The use of 4A molecular sieve: deep drying of air, natural gas, alkanes, refrigerants and other gases and liquids; preparation and purification of argon gas; static drying of drug packaging, electronic components and perishable substances; as dehydrants in paint, fuel and paint.

5A molecular sieve uses: pressure swing adsorption, air purification, dehydration and carbon dioxide.

13X molecular sieve uses: air separation unit gas purification, removal of water and carbon dioxide; natural gas, liquefied petroleum gas, liquid hydrocarbon drying and desulfurization; general gas deep drying.

Technical Index

Air Separation Molecular Sieve Typical Physical Properties
Items Unit 4*6 Mesh 3*5 Mesh
Bead Size mm 3.0-5.0 4.0-6.0
Bulk Density g/ml ≥ 0.65-0.80 0.65-0.80
Equilibrium Water Capacity @ 25℃ wt% ≥ 24.0-27.0 24.0-27.0
Equilibrium Carbon Dioxide Capacity wt% ≥ 18 18
Heat of Adsorption BTU/lb of H2O 1800 1800
Crush Strength Point Contact N ≥ 80-130 80-130
Variation Coefficient - 0.3 0.3
Attrition Rate wt% ≤ 0.1 0.1
Size Qualification % ≥ 97 97
Package Moisture wt% ≤ 1.5 1.5
The interval value of the indexes above are on the basis of the different grade of Air Separation Molecular Sieve

Regeneration:

Regeneration in typical cyclic systems constitutes removal of the adsorbate from the molecular sieve bed by heating and purging with a carrier gas. Sufficient heat must be applied to raise the temperature of the adsorbate, the adsorbent and the vessel to vaporize the liquid and offset the heat of wetting the molecular-sieve surface. The bed temperature is critical in regeneration. Bed temperatures in the 175-260° range are usually employed for type 3A. This lower range minimizes polymerization of olefins on the molecular sieve surfaces when such materials are present in the gas. Slow heat up is recommended since most olefinic materials will be removed at minimum temperatures; 4A, 5A and 13X sieves require temperatures in the 200-315 °C range.

After regeneration, a cooling period is necessary to reduce the molecular sieve temperature to within 15° of the temperature of the stream to be processed. This is most conveniently done by using the same gas stream as for heating, but with no heat input. For optimum regeneration, gas flow should be countercurrent to adsorption during the heat up cycle, and concurrent (relative to the process stream) during cooling. Alternatively, small quantities of molecular sieves may be dried in the absence of a purge gas by oven heating followed by slow cooling in a closed system, such as a desiccator.

Packaging & Shipping


Packing specification: 25kg plastic woven bag or ton bag or bucket packaging, also can be packed according to your requirement.


Product transport requirements: keep dry, away from inflammable, corrodible, toxic goods.

Inquiry Cart 0